Quality Control and Artefacts in Magnetic Resonance Imaging

preview-18
  • Quality Control and Artefacts in Magnetic Resonance Imaging Book Detail

  • Author : Donald McRobbie
  • Release Date : 2017-01-31
  • Publisher : Institute of Physics and Engineering in Medicine
  • Genre :
  • Pages :
  • ISBN 13 : 9781903613610
  • File Size : 69,69 MB

Quality Control and Artefacts in Magnetic Resonance Imaging by Donald McRobbie PDF Summary

Book Description: Quality Control and Artefacts in Magnetic Resonance Imaging is an authoritative, comprehensive and practical guide for all medical imaging professionals with an interest in evaluating and assuring image quality and scanner performance in MRI. Written by leading UK experts, the report is a major revision of IPEM Report 80: Quality Control in Magnetic Resonance Imaging. The report is in two parts. Part I deals with quality control, with chapters on test object design and test materials, signal parameter measurement (signal-to-noise ratio, ghosting, etc.), geometric parameters (resolution, distortion), slice parameters (position, width and profile), relaxometry and contrast. For each parameter a consistent and systematic structure provides a literature review with reference to current international standards, parameter definition, description of test methods, practical guidance including frequency of measurement, analysis and interpretation of results, and pitfalls. A specialist QC chapter is a new and unique feature providing guidance relating to specific clinical and research techniques: field mapping, diffusion, BOLD fMRI, voxel-based morphometry, dynamic contrast-enhanced MRI, quantitative velocity mapping, spectroscopy, and ultra-high field MRI. Part II provides a comprehensive and exhaustive encyclopaedia of MRI artefacts both common and rare arising from technical limitations and faults, patient and organ motion, tissue properties, intrinsic MR physics, and reconstruction limitations. Pictorial examples of each artefact from clinical or phantom images are provided along with a detailed explanation of the causes and advice on reducing, avoiding or removing the artefact. A summary table of artefact appearance, causes and remediation will enable readers to diagnose and solve their own artefact problems. The practical nature of the report is underpinned by academic rigour with 269 references and a comprehensive index. Quality Control and Artefacts in Magnetic Resonance is an essential reference for all MRI departments and MRI professionals.

Disclaimer: www.yourbookbest.com does not own Quality Control and Artefacts in Magnetic Resonance Imaging books pdf, neither created or scanned. We just provide the link that is already available on the internet, public domain and in Google Drive. If any way it violates the law or has any issues, then kindly mail us via contact us page to request the removal of the link.

MRI from Picture to Proton

MRI from Picture to Proton

File Size : 58,58 MB
Total View : 4117 Views
DOWNLOAD

MR is a powerful modality. At its most advanced, it can be used not just to image anatomy and pathology, but to investigate organ function, to probe in vivo che